Flexible flat cable is a kind of multi-strand copper stranded conductor with insulating material, through high-tech automation equipment production line through the sheath material pressing the flat cable, with soft, arbitrary bending fold, relative thickness thin, small volume, simple connection, convenient disassembly, etc. We can choose any number and wire spacing, make online more convenient, reduce the size of the products, reduce the production cost, improve production efficiency, suitable for electrical equipment for data transmission in the cable or power transmission.Common specification is 0.5 mm, 0.8 mm and 1.0mm, 1.25mm and 1.5mm, 2.0mm and 2.5mm Various spacing flexible cable wire.
The structure characteristics of flat cable
The flat cable wire core is made of soft structure to ensure flat cable good soft performance.
Using butyl polymer insulation and protection layer material, and improve the flat cable flex characteristics and anticorrosive and hardy properties.
Insulated wire core color separation, provide convenience for flat cable installation.
According to customer needs, increase on both sides of flat cable core wire rope or other load bearing components (yffbj type).
Coaxial cable is also can make communication elevator flat cable
2016年3月22日星期二
2016年3月7日星期一
Introduction of the cause and consequence of power cable fever
Power cable by a certain load current, will be hot, with the increase of load current and cable surface temperature is higher, if not handled in time, the consequences. Such as: polyvinyl chloride (PVC) cable, wire core temperature of 70 degrees is limit considered, low surface temperature will be 5 ~ 10 degrees. So the cable surface temperature under 60 degrees basic is safe, considering from the power maintenance, the lower the temperature, the better, of course.
In the operation of the cable in heating reasons are as follows:
1. Cable conductor resistance does not conform to the requirements, resulting in cable heating phenomenon in running.
2. Cable wide choices, the use of the conductor cross section of the cable is too small, in the operation of the overload phenomenon, after long time use, the heating and cooling of the cable have fever due to unbalanced phenomenon.
3. Arrange too dense, cable installation, ventilation cooling effect is not good, or cable near too close to other sources of heat, affected the normal heat dissipation of the cable, may also cause cable heating phenomenon in running.
4. Joint manufacturing technology is bad, no pressure to close, cause whenelectrified resistance is too large, also will cause the cable to produce hot phenomenon.
5. Cable insulation is not good, cause the insulation resistance is small, also can produce in the operation of the heating phenomenon.
6. Armored cable, local sheath damage cause slow damage to insulation performance, after the water gradually reduce insulation resistance, can cause heating phenomenon in the operation of the cable.
After cable heating phenomenon, if you don't find out why timely troubleshooting, continuous electric cable to continue after the operation will produce heat insulation breakdown phenomenon. Cable causing interphase short circuit trip phenomenon, serious may cause fire.
In the operation of the cable in heating reasons are as follows:
1. Cable conductor resistance does not conform to the requirements, resulting in cable heating phenomenon in running.
2. Cable wide choices, the use of the conductor cross section of the cable is too small, in the operation of the overload phenomenon, after long time use, the heating and cooling of the cable have fever due to unbalanced phenomenon.
3. Arrange too dense, cable installation, ventilation cooling effect is not good, or cable near too close to other sources of heat, affected the normal heat dissipation of the cable, may also cause cable heating phenomenon in running.
4. Joint manufacturing technology is bad, no pressure to close, cause whenelectrified resistance is too large, also will cause the cable to produce hot phenomenon.
5. Cable insulation is not good, cause the insulation resistance is small, also can produce in the operation of the heating phenomenon.
6. Armored cable, local sheath damage cause slow damage to insulation performance, after the water gradually reduce insulation resistance, can cause heating phenomenon in the operation of the cable.
After cable heating phenomenon, if you don't find out why timely troubleshooting, continuous electric cable to continue after the operation will produce heat insulation breakdown phenomenon. Cable causing interphase short circuit trip phenomenon, serious may cause fire.
![]() |
| http://www.anytecable.com |
2016年2月24日星期三
The encoder cables
What is the encoder? Maybe a lot of people are unfamiliar with it, today I will briefly introduce to you what is encoder. At the same time, the more important is I have the detailed interpretation of the connected encoder cables and equipment.
Encoder is to signal (such as bittorrent) or data, converted to available in the form of communication, signal transmission and storage of equipment. Encoder angular displacement or linear displacement is converted into electrical signals, the former is called the encoder, which is referred to as a yardstick. According to the readout method encoder can be divided into two kinds of contact type and non-contact. Contact output, using brush a brush contact conductive area or insulation area to represent the state of the code is "1" or "0"; Acceptance of non-contact sensor is photosensitive components or magnetic sensor, using photosensitive element to pervious to light and opaque to represent the state of the code is "1" or "0", by "1" and "0" binary code to collect to physical signal is converted into machine code can read the electrical signals to communications, transmission and storage.
As a measure, monitor and control cable is suitable for use in machine tool manufacturing, complete sets of equipment installation engineering, power stations, heating and air conditioning, refrigeration equipment, office automatic equipment, as well as the data processing system, etc.
And on the encoder cable generally have RVVSP RVVYSP, drag chain to wring TRVVP etc cable type, its structure is: the guide body: multi-strand fine ground tin plated copper wire, strong corrosion resistance. Unique edge: special hard hot flame retardant PVC insulated., yan color: meet DIN47100, two groups of each wire pair (1, 2 black/white/red distinctions). Inside the shielding: aluminum foil shield got package. Row streamline: (optional) specifications with conductor drainage effect, shielded wire and convenient for processing. Knitting weaving, bare copper wire or tin plated copper wire braided shielding (optional).
Changzhou Anytekabel Co.,Ltd. is manufacturer specializing in the production of encoder cable, the company using the German advanced technology and mature management system, the encoder cable has reached international advanced standards, by the domestic and foreign customers consistent high praise, sales engineer is committed to let customers access to affordable cable.
Encoder is to signal (such as bittorrent) or data, converted to available in the form of communication, signal transmission and storage of equipment. Encoder angular displacement or linear displacement is converted into electrical signals, the former is called the encoder, which is referred to as a yardstick. According to the readout method encoder can be divided into two kinds of contact type and non-contact. Contact output, using brush a brush contact conductive area or insulation area to represent the state of the code is "1" or "0"; Acceptance of non-contact sensor is photosensitive components or magnetic sensor, using photosensitive element to pervious to light and opaque to represent the state of the code is "1" or "0", by "1" and "0" binary code to collect to physical signal is converted into machine code can read the electrical signals to communications, transmission and storage.
As a measure, monitor and control cable is suitable for use in machine tool manufacturing, complete sets of equipment installation engineering, power stations, heating and air conditioning, refrigeration equipment, office automatic equipment, as well as the data processing system, etc.
And on the encoder cable generally have RVVSP RVVYSP, drag chain to wring TRVVP etc cable type, its structure is: the guide body: multi-strand fine ground tin plated copper wire, strong corrosion resistance. Unique edge: special hard hot flame retardant PVC insulated., yan color: meet DIN47100, two groups of each wire pair (1, 2 black/white/red distinctions). Inside the shielding: aluminum foil shield got package. Row streamline: (optional) specifications with conductor drainage effect, shielded wire and convenient for processing. Knitting weaving, bare copper wire or tin plated copper wire braided shielding (optional).
Changzhou Anytekabel Co.,Ltd. is manufacturer specializing in the production of encoder cable, the company using the German advanced technology and mature management system, the encoder cable has reached international advanced standards, by the domestic and foreign customers consistent high praise, sales engineer is committed to let customers access to affordable cable.
2016年2月18日星期四
Several questions need attention when install fire-resistant cable
Fire resistance cable can still maintain the normal work of the line for a period of time under the condition of combustion, that is to say in case there is on fire, fire-resistant cable won't suddenly burning, it still can maintain the normal power supply for a period of time. This feature determines the fire-resistant cable in modern urban and industrial construction plays an important role, because once the fire, control, monitor, guide and alarm systems such as power supply circuit must maintain normal work.
Fire-resistant cable applications:
Fire-resistant cable is mainly used in emergency power supply to the user of fire equipment, fire alarm equipment, ventilation and smoke exhaust, guide line lights, emergency power socket, the elevator for the emergency power supply circuit.
Staff need to pay attention to the following questions when install fire-resistant cable:
1. When fire-resistant cable used for cable populated in the cable tunnels, cable interlayer, or inflammable places near tubing, oil depot, fire-resistant cable shall, first of all, choose A category. Despite the situation, and the less number of cable configuration, should choose B type fireproof cables.
2. Fire-resistant cable mostly used as emergency power supply circuit, the normal work of the requirements of fire. Due to the fire when the environment temperature has risen sharply, to ensure the transmission capacity of lines, lower pressure drop, long for the power supply circuit and the circuit of the voltage drop strictly limit allowed, fire-resistant cable should be at least one.
3. Fire-resistant flexible cable cannot be used as a high temperature resistant cable.
4. In order to reduce cable joint failure probability in fire accident, should try to reduce the amount of joint in the installation, to guarantee the normal work of the lines in the fire. If you need to do to branch connection, deal with joint completes the fire prevention.
Fire-resistant cable applications:
Fire-resistant cable is mainly used in emergency power supply to the user of fire equipment, fire alarm equipment, ventilation and smoke exhaust, guide line lights, emergency power socket, the elevator for the emergency power supply circuit.
Staff need to pay attention to the following questions when install fire-resistant cable:
1. When fire-resistant cable used for cable populated in the cable tunnels, cable interlayer, or inflammable places near tubing, oil depot, fire-resistant cable shall, first of all, choose A category. Despite the situation, and the less number of cable configuration, should choose B type fireproof cables.
2. Fire-resistant cable mostly used as emergency power supply circuit, the normal work of the requirements of fire. Due to the fire when the environment temperature has risen sharply, to ensure the transmission capacity of lines, lower pressure drop, long for the power supply circuit and the circuit of the voltage drop strictly limit allowed, fire-resistant cable should be at least one.
3. Fire-resistant flexible cable cannot be used as a high temperature resistant cable.
4. In order to reduce cable joint failure probability in fire accident, should try to reduce the amount of joint in the installation, to guarantee the normal work of the lines in the fire. If you need to do to branch connection, deal with joint completes the fire prevention.
2016年1月5日星期二
The reason of power cable fault
The reason of power cable fault
1. Insulation aging metamorphism
Electric power cable insulation will suffer with effect of thermal, chemical and mechanical action, so that the insulating medium physical and chemical changes, and decreased the insulation of the medium level. Insulation be affected with damp be affected with damp. The middle connector or terminal head caused by structure and seal or the installation quality is bad insulation be affected with damp be affected with damp; Lead manufacturing cable package leaving sand holes or cracks and other defects, also can make the cable to be affected with damp be affected with damp.
2. Cable overheat
There are many causes of the cable overheating. Internal cause is the cable insulation inside the air gap caused by free local heat, so that insulation carbonization. External cause is installed on the cable populated areas, cable tunnel and cable, wear in the drying tube and with access to cable, cable due to cable overload or bad heat dissipation, and make the insulation damage of acceleration.
3. Mechanical damage
Mainly refers to the external force of cable damage. This is mainly due to the vehicle vibration and other mechanical action, make the cable shape. Cable deformation in bending excessive, damaged the internal insulation or cause insulation inside the air gap.
4. Sheath corrosion
Due to electrolysis corrosion or chemical action make the power cable lead package, because of the nature and degree of corrosion, lead covered with red, yellow, orange and pale yellow sponge compound or similar pores.
5. Overvoltage caused the breakdown
Atmosphere overvoltage and inner overvoltage of cable insulation breakdown caused by stress exceeds allowable values. And analyze the actual fault show that many outdoor terminal fault, is caused by atmospheric overvoltage.
6. Middle connector, terminal head of design and production process problems
Stripping semiconductor, damage to internal insulation or insulating surface particles, dust and other impurities; Cable head seal bad, make the internal insulation has moisture, cause insulation be affected with damp be affected with damp; Cable joint process is not standard, non-standard seal, cause ground; Production environment humidity is big, cause the production site (cable head) insulation integrity of be affected with damp be affected with damp; Cable grounding errors, causing the ground wire forming circulation or rupture.
1. Insulation aging metamorphism
Electric power cable insulation will suffer with effect of thermal, chemical and mechanical action, so that the insulating medium physical and chemical changes, and decreased the insulation of the medium level. Insulation be affected with damp be affected with damp. The middle connector or terminal head caused by structure and seal or the installation quality is bad insulation be affected with damp be affected with damp; Lead manufacturing cable package leaving sand holes or cracks and other defects, also can make the cable to be affected with damp be affected with damp.
2. Cable overheat
There are many causes of the cable overheating. Internal cause is the cable insulation inside the air gap caused by free local heat, so that insulation carbonization. External cause is installed on the cable populated areas, cable tunnel and cable, wear in the drying tube and with access to cable, cable due to cable overload or bad heat dissipation, and make the insulation damage of acceleration.
3. Mechanical damage
Mainly refers to the external force of cable damage. This is mainly due to the vehicle vibration and other mechanical action, make the cable shape. Cable deformation in bending excessive, damaged the internal insulation or cause insulation inside the air gap.
4. Sheath corrosion
Due to electrolysis corrosion or chemical action make the power cable lead package, because of the nature and degree of corrosion, lead covered with red, yellow, orange and pale yellow sponge compound or similar pores.
5. Overvoltage caused the breakdown
Atmosphere overvoltage and inner overvoltage of cable insulation breakdown caused by stress exceeds allowable values. And analyze the actual fault show that many outdoor terminal fault, is caused by atmospheric overvoltage.
6. Middle connector, terminal head of design and production process problems
Stripping semiconductor, damage to internal insulation or insulating surface particles, dust and other impurities; Cable head seal bad, make the internal insulation has moisture, cause insulation be affected with damp be affected with damp; Cable joint process is not standard, non-standard seal, cause ground; Production environment humidity is big, cause the production site (cable head) insulation integrity of be affected with damp be affected with damp; Cable grounding errors, causing the ground wire forming circulation or rupture.
2015年12月21日星期一
Manufacturing process of Nylon sheathed wire
Due to the nature of nylon material have different from ordinary plastic, therefore we put forward some unique technical requirements in the extrusion process.
Drying process. Because the nylon material is medium polarity, easy absorption of moisture, according to Nylon sheathed wire material manufacturer, when the nylon material moisture content exceeds 0.3%, cannot squeeze, found in the actual production process, the nylon is expected to be affected with damp be affected with damp, extrusion sheath will blister, such as foam, granular material or damaged. Nylon material itself with vacuum bag vacuum packaging, not broken packages can be directly put into use, but such as transportation damage, sealed or open package are not finished in time, etc., must be dried before use.
So be affected with damp be affected with damp dry nylon material should be done before using. Had better use of pumping air into vacuum state, rotating barrel heating to remove moisture, each drying amount shall not exceed 3/5 dryer volume. Such as the capacity is too big, inside the dryer materials difficult to rotate, cause uneven heating, short time water is difficult to remove all, time is long can make the yellow part material oxidation, unable to meet the requirements of sending out surface. Vacuum degree of vacuum should reach more than 0.05 MPa, or it will be hard to remove moisture, if by steam heating, to control the heating temperature, amount of water vapor temperature appropriate for 80 + / - 50 ℃, the heating temperature is too high the nylon wire material oxidation and become yellow.
Drying process. Because the nylon material is medium polarity, easy absorption of moisture, according to Nylon sheathed wire material manufacturer, when the nylon material moisture content exceeds 0.3%, cannot squeeze, found in the actual production process, the nylon is expected to be affected with damp be affected with damp, extrusion sheath will blister, such as foam, granular material or damaged. Nylon material itself with vacuum bag vacuum packaging, not broken packages can be directly put into use, but such as transportation damage, sealed or open package are not finished in time, etc., must be dried before use.
So be affected with damp be affected with damp dry nylon material should be done before using. Had better use of pumping air into vacuum state, rotating barrel heating to remove moisture, each drying amount shall not exceed 3/5 dryer volume. Such as the capacity is too big, inside the dryer materials difficult to rotate, cause uneven heating, short time water is difficult to remove all, time is long can make the yellow part material oxidation, unable to meet the requirements of sending out surface. Vacuum degree of vacuum should reach more than 0.05 MPa, or it will be hard to remove moisture, if by steam heating, to control the heating temperature, amount of water vapor temperature appropriate for 80 + / - 50 ℃, the heating temperature is too high the nylon wire material oxidation and become yellow.
2015年12月9日星期三
H07RN-F cable wire
H07RN-F rubber cable is mainly suitable for heavy equipment such as: engine, agricultural machinery, large tools and construction equipment. This wire can be used for the dry and wet indoor, can also be dew outside or in damp environment, high flexibility, has to withstand weather, oil/grease, mechanical and thermal stress. Applications include processing equipment, mobile power supply, construction site, stage and audio-visual equipment, port area and DAMS. Also suitable for gypsum fixing device, temporary buildings and residential, barracks drainage and sewage treatment, the cold and harsh industrial environments. At the same time also have certain flame retardant, antioxidant and uv protection. No harmful material, conform to the ROHS standard. This kind of wire maximum working temperature of 90 ℃, the minimum can reach to 40 ℃.
2015年12月2日星期三
PVC cable servo motor
So-called servo motor cable by the signal wire and power cable conductor, its special design makes it ideal for automation applications, such as: drag chain system, automatic loading and unloading equipment, plug-in components, gantry crane robot, the use of machine tools and other need to keep on moving, the whole tin copper braiding makes it suitable for the electronic jamming signal transmission, can also be applied to reduce the electromagnetic radiation. The cable diameter small, save the cable installation required space has excellent resistance to mineral oils and high wear resistance, and high density of weaving to ensure without interference signal and the pulse transmission, softer when in low temperature. In terms of performance, the working voltage is 0.6/1 kv, temperature range of use: mobile installation: - 5 ℃ to + 70 ℃, fixed installation: to 40 ℃ to + 80 ℃. In terms of structure: it is made of many strands of fine twisted copper conductors, meet VDE0295 / IEC228 5 classes; Insulation is composed of very low capacitance PVC/TPE compounds, outer sheath is highly wear resistant PVC base mixture, insulation and outer sheath can be customized according to customer's request. Core aspects, especially the power line and signal of wire twisted together, fill in the strengthening core, braided shielding is tin plated copper wire weaving, optical cover about 85%.
2015年11月25日星期三
Twisted-pair communication cable
Twisted-pair communication cable structure
All plastic communication cable in the cable core is mainly composed of conductor, wire insulation, cable core insulation covering layer, cable tie and etc.
1. The core is composed of metal wires and insulation. Wires are used to transmit electrical signals, with good electrical conductivity, enough softness and mechanical strength, at the same time also require easy processing, installation and use. Soft quality for electrolytic copper wire, copper wire of the wire diameter is 0.32, 0.4, 0.5, 0.6, 0.5 mm etc. Five.
2. Insulation and insulation structure
All plastic communication cable in the city of conductor insulation mainly USES the high density polyethylene, polypropylene, or ethylene propylene copolymer, such as polymer, called polyolefin plastics.
3. The conductor lay: has the twisted and star twisted two kinds, core wires twisting are commonly used for ground way.
4. Cable conductor chromatography
The cable conductor of the cable chromatography could be divided into two types: general chromatography and whole spectrum.
(1) general chromatography communication cable
General chromatography to wring concentric communication cable has rarely used.
(2) the whole spectrum communication cable
The meaning of the whole spectrum "refers to any pair of conductor of the cable, can all be units at all levels of cable tie color and line of color to identify, in other words to qualification, can find outlet, outlet can say to qualify.
(1) the whole chromatogram to wring the concentric cable core (rarely)
(2) the whole spectrum of ground unit type cable core
All chromatographic to ground unit type cable conductor was most used in such a cable. The code it is made of white (W), red (R) and black (B), yellow (Y), purple (V) as the pilot color (on behalf of a line), blue (Bl), orange (O), green (G), brown (Br), gray (S) as a circular color (B line) ten kinds of color composition to the whole spectrum line to 25, said 25 to the basic unit of U.
All plastic communication cable in the cable core is mainly composed of conductor, wire insulation, cable core insulation covering layer, cable tie and etc.
1. The core is composed of metal wires and insulation. Wires are used to transmit electrical signals, with good electrical conductivity, enough softness and mechanical strength, at the same time also require easy processing, installation and use. Soft quality for electrolytic copper wire, copper wire of the wire diameter is 0.32, 0.4, 0.5, 0.6, 0.5 mm etc. Five.
2. Insulation and insulation structure
All plastic communication cable in the city of conductor insulation mainly USES the high density polyethylene, polypropylene, or ethylene propylene copolymer, such as polymer, called polyolefin plastics.
3. The conductor lay: has the twisted and star twisted two kinds, core wires twisting are commonly used for ground way.
4. Cable conductor chromatography
The cable conductor of the cable chromatography could be divided into two types: general chromatography and whole spectrum.
(1) general chromatography communication cable
General chromatography to wring concentric communication cable has rarely used.
(2) the whole spectrum communication cable
The meaning of the whole spectrum "refers to any pair of conductor of the cable, can all be units at all levels of cable tie color and line of color to identify, in other words to qualification, can find outlet, outlet can say to qualify.
(1) the whole chromatogram to wring the concentric cable core (rarely)
(2) the whole spectrum of ground unit type cable core
All chromatographic to ground unit type cable conductor was most used in such a cable. The code it is made of white (W), red (R) and black (B), yellow (Y), purple (V) as the pilot color (on behalf of a line), blue (Bl), orange (O), green (G), brown (Br), gray (S) as a circular color (B line) ten kinds of color composition to the whole spectrum line to 25, said 25 to the basic unit of U.
2015年11月16日星期一
The characteristics and applications of the oil resistant cable
Oil resistant cable is a kind of anti-static oil resistant special measuring cable, composed by the many strands of copper conductors, fluorine plastic insulation, TPV thermoplastic elastic inner sheath, galvanized steel wire carrying strengthening layer, polyurethane outer sheath. Extruded polyethylene fluorine plastic insulation materials outside the many strands of copper conductors, extruded TPV thermoplastic elastic body sheath outside the multicore cable, the sheath in TPV thermoplastic elastic body braided galvanized steel wire carrying strengthening layer, strengthen layer in the galvanized steel wire carrying out package polyurethane sheath base.
Oil resistant cable is weak signal measurement cable, suitable for environment that easy to produce the special working, such as static electricity, fuel oil pool with antistatic, oil resistant, tensile and bending properties, cable minimum bending radius should not less than five times of the cable diameter, the largest cable tension under 200kg, number of electric cable winding bend down more than 3000 times. Oil resistant cable applies to the metallurgical, petroleum, chemical industry and power plants and other industrial and mining enterprises, under the condition of high temperature and harsh environment, such as acid, alkali, oil and low temperature conditions as various kinds of electrical, instrumentation and automatic device of cables, for ac rated voltage up to and including 450/750v control, circuit monitor and protection and situations.
The following is oil resistant cable main models produced by Anyte cable:
YQ, YQW light rubber flexible cable, apply for mobile electrical equipments and tools
YZ, YZW medium-sized rubber flexible cable, Used for various portable electric equipments and tools
YC, YCW heavy rubber flexible cable, Used for various portable electric equipment, can withstand the larger the effect of external mechanical forces
Anytekabel Co.,Ltd. flexible cable Christmas day sale 2015
Oil resistant cable is weak signal measurement cable, suitable for environment that easy to produce the special working, such as static electricity, fuel oil pool with antistatic, oil resistant, tensile and bending properties, cable minimum bending radius should not less than five times of the cable diameter, the largest cable tension under 200kg, number of electric cable winding bend down more than 3000 times. Oil resistant cable applies to the metallurgical, petroleum, chemical industry and power plants and other industrial and mining enterprises, under the condition of high temperature and harsh environment, such as acid, alkali, oil and low temperature conditions as various kinds of electrical, instrumentation and automatic device of cables, for ac rated voltage up to and including 450/750v control, circuit monitor and protection and situations.
The following is oil resistant cable main models produced by Anyte cable:
YQ, YQW light rubber flexible cable, apply for mobile electrical equipments and tools
YZ, YZW medium-sized rubber flexible cable, Used for various portable electric equipments and tools
YC, YCW heavy rubber flexible cable, Used for various portable electric equipment, can withstand the larger the effect of external mechanical forces
Anytekabel Co.,Ltd. flexible cable Christmas day sale 2015
2015年11月9日星期一
What kind of cable does Machine tool companies use
Our country is large machine tool production country, but machine tools has been the deficit of import and export business. In order to reduce import and export trade deficit, in the future market competition, the international machine tool industry will further improve product quality, reduce production costs.
With the rapid development of the machine tool industry, the growing market demand of rubber sets of cables. Rubber cable consists of many strands of fine copper wire as the conductor, the outsourcing of rubber insulation and rubber sheath a soft removable cable varieties. In general, including general rubber flexible cable, welding machine cables, submersible motor cable, radio device cable and photography lighting cables and other varieties. Rubber flexible cable is better, through the reasonable coordination, abrasion resistance, flame retardant, insulation, high temperature resistant, and special requirements, such as ants, mouldproof, rat can be made. So when the rubber cable machine tool enterprises the main choice, Anyte's production of rubber cable H07RN-F complying with CE certification, national standard of YC, YZ, whether machine tool enterprises export or sale in domestic market, we have to meet the requirements of corresponding products, machine tool products and Anyte cable will stand together regardless of situation.
With the rapid development of the machine tool industry, the growing market demand of rubber sets of cables. Rubber cable consists of many strands of fine copper wire as the conductor, the outsourcing of rubber insulation and rubber sheath a soft removable cable varieties. In general, including general rubber flexible cable, welding machine cables, submersible motor cable, radio device cable and photography lighting cables and other varieties. Rubber flexible cable is better, through the reasonable coordination, abrasion resistance, flame retardant, insulation, high temperature resistant, and special requirements, such as ants, mouldproof, rat can be made. So when the rubber cable machine tool enterprises the main choice, Anyte's production of rubber cable H07RN-F complying with CE certification, national standard of YC, YZ, whether machine tool enterprises export or sale in domestic market, we have to meet the requirements of corresponding products, machine tool products and Anyte cable will stand together regardless of situation.
2015年11月3日星期二
Introduction of which industry drag chain cables apply to
Flexible Drag chain cable important application: industrial electronic system, automatically generating line, storage facilities, robot, fire fighting system, crane, nc machine tools and metallurgical industry.
In unit facilities need to move back and forth, in order to prevent the cable tangle, loss, pulled off, hang and scattered, often put the cable in the cable drag chain, protection for cable, and cable can also with the drag chain to carry out the move back and forth, this can follow the drag chain moving back and forth and not easy loss of high flexible cable, special cable was called drag chain usually can also be called the towing cable, tank chain cables.
Drag chain cable products model
TRVV: copper nitrile butadiene, PVC insulated, nitrile butadiene PVC sheathed Drag chain cable.
TRVVP: copper nitrile butadiene PVC insulation, nitrile butadiene PVC sheathed, soft sheath tin plated copper wire mesh weaving to drag chain cables.
TRVVSP: copper nitrile butadiene PVC insulation, nitrile butadiene and sheath shielding Drag chain cable.
RVVYP: copper core special insulation, nitrile butadiene nitrile butadiene mixed hybrid special sheath oil resistant total shielding drag chain cable.
Conductor: many strands of super fine fine ground oxygen-free copper wire, 0.1 + / - 0.004 mm in diameter. If you have special requirements, you can select other types of copper wire according to customer technical indicators.
Insulation: special hybrid nitrile butadiene PVC insulation.
Color: according to the customer designated.
Shielding: tinned copper wire mesh weaving density by more than 85%
Sheath: mixed nitrile butadiene PVC special bending resistance, oil resistance, abrasion resistance, waterproof jacket.
Drag chain cables types is various, some conclusions from single core to 60 cores, single core area is covering all of the class 0.08-60 models.
Changzhou Anytekabel Co.,Ltd. is professional company supply System electrical connection and installation solutions for Equipment manufacturing industry clients; Has developed and produced high function suitable for various conditions cable products, together to supply customers with cable wire processing and professional electrical wire control installation services.
In unit facilities need to move back and forth, in order to prevent the cable tangle, loss, pulled off, hang and scattered, often put the cable in the cable drag chain, protection for cable, and cable can also with the drag chain to carry out the move back and forth, this can follow the drag chain moving back and forth and not easy loss of high flexible cable, special cable was called drag chain usually can also be called the towing cable, tank chain cables.
Drag chain cable products model
TRVV: copper nitrile butadiene, PVC insulated, nitrile butadiene PVC sheathed Drag chain cable.
TRVVP: copper nitrile butadiene PVC insulation, nitrile butadiene PVC sheathed, soft sheath tin plated copper wire mesh weaving to drag chain cables.
TRVVSP: copper nitrile butadiene PVC insulation, nitrile butadiene and sheath shielding Drag chain cable.
RVVYP: copper core special insulation, nitrile butadiene nitrile butadiene mixed hybrid special sheath oil resistant total shielding drag chain cable.
Conductor: many strands of super fine fine ground oxygen-free copper wire, 0.1 + / - 0.004 mm in diameter. If you have special requirements, you can select other types of copper wire according to customer technical indicators.
Insulation: special hybrid nitrile butadiene PVC insulation.
Color: according to the customer designated.
Shielding: tinned copper wire mesh weaving density by more than 85%
Sheath: mixed nitrile butadiene PVC special bending resistance, oil resistance, abrasion resistance, waterproof jacket.
Drag chain cables types is various, some conclusions from single core to 60 cores, single core area is covering all of the class 0.08-60 models.
Changzhou Anytekabel Co.,Ltd. is professional company supply System electrical connection and installation solutions for Equipment manufacturing industry clients; Has developed and produced high function suitable for various conditions cable products, together to supply customers with cable wire processing and professional electrical wire control installation services.
2015年10月28日星期三
How does flexible cable enterprise develop in the Internet era?
In recent society, many electrical wire cable enterprises are in research and development and sales of flexible cable, flexible cable companies must keep up with the pace of The Times, as the saying goes "no successful enterprises, only in the era of enterprise". Flexible cable companies should maintain the healthy development of Internet era, from the following aspects.
Cable enterprises should first improve the flexible cable products in the international market share, at present China's cable products accounted for 4% in more than twenty countries. Cable companies should be around new products, new channels, and expand the international market. In addition, the cable companies should also improve the internationalized talent proportion, to increase the intensity of international capital, make full use of international capital to promote enterprise development.
Flexible cable industry, is a completely competitive market, competition is very tragic. Cable companies should be actively into high-end cable market, such as aviation wire and cable, high-end development can help cable transformation and upgrading of enterprise success, and improve the flexible cable enterprise competitiveness, jump out of the red sea, into the blue ocean. Cable companies should be doing all the accommodation of industrial chain, the whole value chain, is to do research and development, and to do service, cable companies to the development of wire and cable system.
In addition, the Internet age has many characteristics, such as, zero distance, platform for free. In such an era, cable enterprise must realize the importance of resources structure, cultivate the consciousness of enterprises without boundary, industry chain without measure. Cable companies can be required to research and development of technology and products posted on the Internet, universities and institutions all over the world can undertake, the Internet to gather a group of the most intelligent person, and let this batch of the smartest people service for cable enterprise, is the right way to promote the development of enterprises.
Cable enterprises should first improve the flexible cable products in the international market share, at present China's cable products accounted for 4% in more than twenty countries. Cable companies should be around new products, new channels, and expand the international market. In addition, the cable companies should also improve the internationalized talent proportion, to increase the intensity of international capital, make full use of international capital to promote enterprise development.
Flexible cable industry, is a completely competitive market, competition is very tragic. Cable companies should be actively into high-end cable market, such as aviation wire and cable, high-end development can help cable transformation and upgrading of enterprise success, and improve the flexible cable enterprise competitiveness, jump out of the red sea, into the blue ocean. Cable companies should be doing all the accommodation of industrial chain, the whole value chain, is to do research and development, and to do service, cable companies to the development of wire and cable system.
In addition, the Internet age has many characteristics, such as, zero distance, platform for free. In such an era, cable enterprise must realize the importance of resources structure, cultivate the consciousness of enterprises without boundary, industry chain without measure. Cable companies can be required to research and development of technology and products posted on the Internet, universities and institutions all over the world can undertake, the Internet to gather a group of the most intelligent person, and let this batch of the smartest people service for cable enterprise, is the right way to promote the development of enterprises.
2015年10月13日星期二
Build flexible security cable to build safe city
In emerging markets appear constantly and traditional industry under the condition of market demand continues to increase, will continue to expand domestic demand for security of flexible cable products, the development of China's security cable industry will get enough power, domestic security cable market in the next few years will still presents the fast growth momentum.But it is a good security product, if there is no good quality security cable products, its effect will sell at a discount greatly, and the life security system will be greatly reduced.
For the flexible cable in the security system transfers data, images and other information. As users or engineering procurement of cable products seriously insufficient, causes such as because of the improper selection of building cable products, and affect the quality of the whole system engineering problem, bring certain loss and negative effects. Past the profound lessons, make more and more users and engineering contractor gradually focus on cable and the correct use of the quality of product, and gradually change the engineering use, to the choose and buy of security cable products by price dominant thoughts.
For now, China as the world's one of the most important production base of cable products research and development, currently has a flame retardant fire-resistant, high temperature resistant low temperature resistance, low inductance, low noise, green environmental protection, low smoke zero halogen, ant rat resistance, waterproof and moistureproof, and a series of unique properties and the special structure of cable products, and have formed a certain productive forces. Along with the social requirements for security and system security, through the government, industry, enterprise's extensive publicity, promotion and cooperation, have a new technology of high performance and efficient security cable products will like the western developed countries, is widely used in security system.
Anytekabel Co.,Ltd. dedicated to the research and development and formation of flexible cable, the future will also be followed the pace of times, to create the application of flexible cable in security industry.
For the flexible cable in the security system transfers data, images and other information. As users or engineering procurement of cable products seriously insufficient, causes such as because of the improper selection of building cable products, and affect the quality of the whole system engineering problem, bring certain loss and negative effects. Past the profound lessons, make more and more users and engineering contractor gradually focus on cable and the correct use of the quality of product, and gradually change the engineering use, to the choose and buy of security cable products by price dominant thoughts.
For now, China as the world's one of the most important production base of cable products research and development, currently has a flame retardant fire-resistant, high temperature resistant low temperature resistance, low inductance, low noise, green environmental protection, low smoke zero halogen, ant rat resistance, waterproof and moistureproof, and a series of unique properties and the special structure of cable products, and have formed a certain productive forces. Along with the social requirements for security and system security, through the government, industry, enterprise's extensive publicity, promotion and cooperation, have a new technology of high performance and efficient security cable products will like the western developed countries, is widely used in security system.
Anytekabel Co.,Ltd. dedicated to the research and development and formation of flexible cable, the future will also be followed the pace of times, to create the application of flexible cable in security industry.
2015年10月7日星期三
Analysis of the minimum installation temperature of flexible cable
Flexible cable temperature and the minimum installation of PVC cable material of low temperature brittle temperature must be inseparable relationship. But how do corresponding relationship, have yet to have authority report. Generally higher than the brittle temperature 5 ℃, the probability of impact test specimen cracking is zero. Theoretically, if the impact of the installation when laying at this moment, less than under the condition of test impact can be construction. But here involves a variety of cable type and construction specification and the testing data of the practice of support.
If you want to truly understand the installation temperature and material laying low temperature brittle temperature relations, is a larger research project, from materials, cables, construction construction (or copy) and so on each link of sampling test, the system to find the critical point of damage, so need a lot of resources and manpower support. Once the figure it out, in turn, to the enterprise is also a great feedback.
If there is really no authoritative data support, to GB/T12706 standard higher than the sheath brittle temperature 20 ℃, laying temperature for a given installation. Though with a difference of 20 ℃ to install laying temperature not so accurate, safe allowance is very big, but definitely not due to the construction temperature cracking quality problems. Differ 15 ℃ installing laying temperature is ok, but must strictly control cable type and construction.
If you want to truly understand the installation temperature and material laying low temperature brittle temperature relations, is a larger research project, from materials, cables, construction construction (or copy) and so on each link of sampling test, the system to find the critical point of damage, so need a lot of resources and manpower support. Once the figure it out, in turn, to the enterprise is also a great feedback.
If there is really no authoritative data support, to GB/T12706 standard higher than the sheath brittle temperature 20 ℃, laying temperature for a given installation. Though with a difference of 20 ℃ to install laying temperature not so accurate, safe allowance is very big, but definitely not due to the construction temperature cracking quality problems. Differ 15 ℃ installing laying temperature is ok, but must strictly control cable type and construction.
2015年9月21日星期一
Oil resistant PVC insulated & sheathed Control flex Screened cable
Oil resistant PVC insulated & sheathed Control flex Screened cable
Construction:
Conductor: bare copper strands
Insulation: special heat resistant PVC
Colour code: black cores with consecutive numbers
Stranding: in layers
with PETP foil over the outer layer
Screen: tinned copper braiding
Sheath material: special heat resistant PVC
Sheath colour: grey (RAL 7000)
Technical data
Nominal voltage: DIN VDE UL/CSA Uo/U 300/500 V 600 V
Testing voltage U: 3000 V core/screen: 1000 V
Min. bending radius fixed laying: 5 x d flexible application: 10 x d
Radiation resistance: 8 x 107 cJ/kg
Temperature range: DIN VDE UL/CSA fixed laying: -40/+90 °C up to +105°C
flexible application: +5/+90 °C up to +105°C short time use: +105 °C
Fire performance: flame retardant and self-extinguishing acc. to
IEC 60332-1-2 + EN 60332-1-2, UL VW-1, CSA FT1 FT2
Temperature range up to + 105°C
Construction:
Conductor: bare copper strands
Insulation: special heat resistant PVC
Colour code: black cores with consecutive numbers
Stranding: in layers
with PETP foil over the outer layer
Screen: tinned copper braiding
Sheath material: special heat resistant PVC
Sheath colour: grey (RAL 7000)
Technical data
Nominal voltage: DIN VDE UL/CSA Uo/U 300/500 V 600 V
Testing voltage U: 3000 V core/screen: 1000 V
Min. bending radius fixed laying: 5 x d flexible application: 10 x d
Radiation resistance: 8 x 107 cJ/kg
Temperature range: DIN VDE UL/CSA fixed laying: -40/+90 °C up to +105°C
flexible application: +5/+90 °C up to +105°C short time use: +105 °C
Fire performance: flame retardant and self-extinguishing acc. to
IEC 60332-1-2 + EN 60332-1-2, UL VW-1, CSA FT1 FT2
Temperature range up to + 105°C
![]() |
| Oil resistant cable www.anytecable.com |
2015年9月14日星期一
Anyte LAN CABLE UTP Cat6
LAN CABLE UTP Cat6
The twisted pair lan cable cat6 used for digital communications , applied in buildings cabling system between patch panels and the output of communication.also used in Residential cabling system between the patch panel and output of communication ,meet the 100MHz data communication. Comply with color coding standard of ANSI/TIA/EIA-568-B
Conductor:Solid or stranded with 7 pieces (tinned) copper wire
Meet the UL444 standard HDPE polyethylene insulated
Two-cores twisted pair, total of four pairs,filled by plastic cross
Special aluminum mylar 100% coverage
drain wire:Single or stranded fine (tin plated) copper wires
(Tinned) copper braid or spiral shielding , coverage rate of 85%
Special PVC outer sheath, or a higher standard of low smoke zero halogen flame retardant outer sheath (optional materials can be customized colors)
Comply with standard UL758,UL1581,UL444,TIA/EIA-568,CSA C22.2, ISO/IEC 11801
Transmission frequency of 100MHz, and support for duplex applications
Comply with RoHS standards
Pass UL VW-1 & CSA FT1 vertical flame test
Operating voltage: 30V
Operating temperature range:
Movable Installation: - 5 ° C to +80 ° C fixed installation: -40 ° C to +80 ° C
Flammability rating: IEC60332-1 CM
DC Resistance at 20 ℃ (Ω / KM) <93.8
Operating Temperature 70 ℃
68% of the propagation velocity
Impedance (ohms) 100 ± 15
Flame Propagation Test to IEC 60332 Part 1 (LSOH) Flame Propagation Test to IEC 60332 Part 1 and Part III (LSFROH) halogen acid gas emissions in line with the IEC 60754, Part 1
Smoke emissions tested comply with IEC 61034
The twisted pair lan cable cat6 used for digital communications , applied in buildings cabling system between patch panels and the output of communication.also used in Residential cabling system between the patch panel and output of communication ,meet the 100MHz data communication. Comply with color coding standard of ANSI/TIA/EIA-568-B
Conductor:Solid or stranded with 7 pieces (tinned) copper wire
Meet the UL444 standard HDPE polyethylene insulated
Two-cores twisted pair, total of four pairs,filled by plastic cross
Special aluminum mylar 100% coverage
drain wire:Single or stranded fine (tin plated) copper wires
(Tinned) copper braid or spiral shielding , coverage rate of 85%
Special PVC outer sheath, or a higher standard of low smoke zero halogen flame retardant outer sheath (optional materials can be customized colors)
Comply with standard UL758,UL1581,UL444,TIA/EIA-568,CSA C22.2, ISO/IEC 11801
Transmission frequency of 100MHz, and support for duplex applications
Comply with RoHS standards
Pass UL VW-1 & CSA FT1 vertical flame test
Operating voltage: 30V
Operating temperature range:
Movable Installation: - 5 ° C to +80 ° C fixed installation: -40 ° C to +80 ° C
Flammability rating: IEC60332-1 CM
DC Resistance at 20 ℃ (Ω / KM) <93.8
Operating Temperature 70 ℃
68% of the propagation velocity
Impedance (ohms) 100 ± 15
Flame Propagation Test to IEC 60332 Part 1 (LSOH) Flame Propagation Test to IEC 60332 Part 1 and Part III (LSFROH) halogen acid gas emissions in line with the IEC 60754, Part 1
Smoke emissions tested comply with IEC 61034
2015年9月9日星期三
The reason for ageing of cable
Wire and cable insulation aging is the most direct reason for lower breakdown.Guide min insulation lower mean a lot, according to the practical operation experience, is classified into the following several ways.
1) the external force damage.Now quite a number of cable fault are caused by mechanical damage.Such as: non-standard cable laying installation construction, easy to cause mechanical damage;Sometimes if the injury is not serious, months or even years to lead to injury completely breakdown failure formation, sometimes destroyed fault may occur, directly affect the safety in production.
2) insulation be affected with damp be affected with damp.It is also very common.Such as: cable joint production of unqualified and do joint in humid climate conditions, can make the joint water or mixed with water vapor, time is long gradually damage the insulation of the cable strength and cause failure.
3) the chemical etching.Protective layer due to the long suffering chemical corrosion and electrochemical corrosion, the coating failure, the insulation is reduced, can also lead to cable fault.
4) long-term overload operation.Overload for a long time running, the high temperature will accelerate aging of the insulation, and insulation breakdown.Especially in hot summer, the temperature of the cable often resulted in the breakdown of cable insulation is weak at first, so in the summer, the failure of the cable is much more special.
But Anytekabel Co.,Ltd., the production of wire and cable, cable from the selection of raw materials or are strictly controlled in the process of production, control, makes every effort to do wire, cable, good let you rest assured brand!
![]() |
| Anyte wire cable |
1) the external force damage.Now quite a number of cable fault are caused by mechanical damage.Such as: non-standard cable laying installation construction, easy to cause mechanical damage;Sometimes if the injury is not serious, months or even years to lead to injury completely breakdown failure formation, sometimes destroyed fault may occur, directly affect the safety in production.
2) insulation be affected with damp be affected with damp.It is also very common.Such as: cable joint production of unqualified and do joint in humid climate conditions, can make the joint water or mixed with water vapor, time is long gradually damage the insulation of the cable strength and cause failure.
3) the chemical etching.Protective layer due to the long suffering chemical corrosion and electrochemical corrosion, the coating failure, the insulation is reduced, can also lead to cable fault.
4) long-term overload operation.Overload for a long time running, the high temperature will accelerate aging of the insulation, and insulation breakdown.Especially in hot summer, the temperature of the cable often resulted in the breakdown of cable insulation is weak at first, so in the summer, the failure of the cable is much more special.
But Anytekabel Co.,Ltd., the production of wire and cable, cable from the selection of raw materials or are strictly controlled in the process of production, control, makes every effort to do wire, cable, good let you rest assured brand!
2015年9月6日星期日
Introduction of the flexible cable
Flexible cable - is drag chain movement system, the power transmission material, cable of choice for signal transmission carrier, also known as: drag chain cable, towing cable, mobile cable, robot cable, etc.
Flexible cable conductor structure mainly according to DIN VDE and IEC 228 standard 0295 stranded copper wire structure, sheathed with low viscosity, more Flexible wear-resisting material, to slow the cable wear rate in the continuous moving back and forth.
Flexible cable according to the functional division is mainly divided into: sensor/encoder cable, servo motor cable, robots cable, clean cable, drag chain cable system.
According to the model can be roughly divided into the following categories:
The flexible control cable
1. PVC sheathed flexible control drag chain cable, flame retardant CC101 bending radius: 8x
2. PVC sheathed flexible shielding control drag chain cable, flame retardant CC111 bending radius: 10x
3. PVC sheathed flexible control cable drag chain cable, flame retardant CC120 bending radius: 5x
4. PVC sheathed flexible shielding control drag chain cable, flame retardant CC121 bending radius: 8x
5. PUR sheath flexible control drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC127 bending radius: 8x
6. PUR sheath flexible control shielded drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC117 bending radius: 10x
7. steel wire braided flexible control drag chain cable, uv protection, good low temperature resistance, wear resistance, CC158 bending radius: 10x
8. PETP outer sheath flexible control drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC160 bending radius: 5x
9. PETP sheathed flexible control shielded drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC133 bending radius: 10x
Flexible power cable
10. PVC sheathed flexible power drag chain cable, flame retardant CC305 bending radius: 8x
11. PVC sheathed outside the shield flexible power drag chain cable, flame retardant CC336 bending radius: 10x
12. PETP outer sheath flexible shield drag chain power cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC358 bending radius: 10x
13. PETP outer sheath flexible shield power drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC371 bending radius: 8x
The flexible data/bus cable
14. PVC sheathed flexible drag chain cable block data. CC41 bending radius: 8x
15. PUR outer sheath flexible shield data drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC43 bending radius: 10x
16. PETP outer sheath flexible shield data drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC46 bending radius: 10x
17. PETP drag chain outer sheath flexible shield data cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC48 bending radius: 12x
Flexible servo cable
18. PUR outer sheath servo drag chain flexible shield cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC46 bending radius: 10x
Flexible cable conductor structure mainly according to DIN VDE and IEC 228 standard 0295 stranded copper wire structure, sheathed with low viscosity, more Flexible wear-resisting material, to slow the cable wear rate in the continuous moving back and forth.
Flexible cable according to the functional division is mainly divided into: sensor/encoder cable, servo motor cable, robots cable, clean cable, drag chain cable system.
![]() |
| Anytekabel Co.,Ltd. |
According to the model can be roughly divided into the following categories:
The flexible control cable
1. PVC sheathed flexible control drag chain cable, flame retardant CC101 bending radius: 8x
2. PVC sheathed flexible shielding control drag chain cable, flame retardant CC111 bending radius: 10x
3. PVC sheathed flexible control cable drag chain cable, flame retardant CC120 bending radius: 5x
4. PVC sheathed flexible shielding control drag chain cable, flame retardant CC121 bending radius: 8x
5. PUR sheath flexible control drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC127 bending radius: 8x
6. PUR sheath flexible control shielded drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC117 bending radius: 10x
7. steel wire braided flexible control drag chain cable, uv protection, good low temperature resistance, wear resistance, CC158 bending radius: 10x
8. PETP outer sheath flexible control drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC160 bending radius: 5x
9. PETP sheathed flexible control shielded drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC133 bending radius: 10x
Flexible power cable
10. PVC sheathed flexible power drag chain cable, flame retardant CC305 bending radius: 8x
11. PVC sheathed outside the shield flexible power drag chain cable, flame retardant CC336 bending radius: 10x
12. PETP outer sheath flexible shield drag chain power cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC358 bending radius: 10x
13. PETP outer sheath flexible shield power drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC371 bending radius: 8x
The flexible data/bus cable
14. PVC sheathed flexible drag chain cable block data. CC41 bending radius: 8x
15. PUR outer sheath flexible shield data drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC43 bending radius: 10x
16. PETP outer sheath flexible shield data drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC46 bending radius: 10x
17. PETP drag chain outer sheath flexible shield data cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC48 bending radius: 12x
Flexible servo cable
18. PUR outer sheath servo drag chain flexible shield cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC46 bending radius: 10x
2015年9月1日星期二
Use requirement and structure characteristics of elevator cable
Using characteristics
1. the cable should be free hanging before use, fully to back twist and the cable to strengthen the core should be fixed, sustain tension at the same time;
2. cable, rows should be in the running, cable with the elevator to move up and down, moving, bending is frequent, soft, flexible;
3. cable, vertical demands a certain tensile strength;
4. work environment with oil to fire, elevator cable requirement is secondary;
5. small diameter, light weight.
Structure characteristics
1. USES the 0.2mm round copper wire bundle heave, winding and the isolation between conductor and insulation layer, into a higher stranded cable when increase the soft cable, bending performance;
2. Increasing cable strengthening core cable, inherit the mechanical strain, strengthening core using materials such as nylon rope, wire rope, in order to increase the tensile strength of the cable;
3. YTF cable made by neoprene sheath, in order to improve the weatherability of the cable and don't delay flammability.
Anytekabel Co.,Ltd.(www.anytecable.com)
1. the cable should be free hanging before use, fully to back twist and the cable to strengthen the core should be fixed, sustain tension at the same time;
2. cable, rows should be in the running, cable with the elevator to move up and down, moving, bending is frequent, soft, flexible;
3. cable, vertical demands a certain tensile strength;
4. work environment with oil to fire, elevator cable requirement is secondary;
5. small diameter, light weight.
Structure characteristics
1. USES the 0.2mm round copper wire bundle heave, winding and the isolation between conductor and insulation layer, into a higher stranded cable when increase the soft cable, bending performance;
2. Increasing cable strengthening core cable, inherit the mechanical strain, strengthening core using materials such as nylon rope, wire rope, in order to increase the tensile strength of the cable;
3. YTF cable made by neoprene sheath, in order to improve the weatherability of the cable and don't delay flammability.
Anytekabel Co.,Ltd.(www.anytecable.com)
订阅: