2015年10月28日星期三

How does flexible cable enterprise develop in the Internet era?

In recent society, many electrical wire cable enterprises are in research and development and sales of flexible cable, flexible cable companies must keep up with the pace of The Times, as the saying goes "no successful enterprises, only in the era of enterprise". Flexible cable companies should maintain the healthy development of Internet era, from the following aspects.
Cable enterprises should first improve the flexible cable products in the international market share, at present China's cable products accounted for 4% in more than twenty countries. Cable companies should be around new products, new channels, and expand the international market. In addition, the cable companies should also improve the internationalized talent proportion, to increase the intensity of international capital, make full use of international capital to promote enterprise development.

Flexible cable industry, is a completely competitive market, competition is very tragic. Cable companies should be actively into high-end cable market, such as aviation wire and cable, high-end development can help cable transformation and upgrading of enterprise success, and improve the flexible cable enterprise competitiveness, jump out of the red sea, into the blue ocean. Cable companies should be doing all the accommodation of industrial chain, the whole value chain, is to do research and development, and to do service, cable companies to the development of wire and cable system.
In addition, the Internet age has many characteristics, such as, zero distance, platform for free. In such an era, cable enterprise must realize the importance of resources structure, cultivate the consciousness of enterprises without boundary, industry chain without measure. Cable companies can be required to research and development of technology and products posted on the Internet, universities and institutions all over the world can undertake, the Internet to gather a group of the most intelligent person, and let this batch of the smartest people service for cable enterprise, is the right way to promote the development of enterprises.

2015年10月13日星期二

Build flexible security cable to build safe city

In emerging markets appear constantly and traditional industry under the condition of market demand continues to increase, will continue to expand domestic demand for security of flexible cable products, the development of China's security cable industry will get enough power, domestic security cable market in the next few years will still presents the fast growth momentum.But it is a good security product, if there is no good quality security cable products, its effect will sell at a discount greatly, and the life security system will be greatly reduced.
For the flexible cable in the security system transfers data, images and other information. As users or engineering procurement of cable products seriously insufficient, causes such as because of the improper selection of building cable products, and affect the quality of the whole system engineering problem, bring certain loss and negative effects. Past the profound lessons, make more and more users and engineering contractor gradually focus on cable and the correct use of the quality of product, and gradually change the engineering use, to the choose and buy of security cable products by price dominant thoughts.

For now, China as the world's one of the most important production base of cable products research and development, currently has a flame retardant fire-resistant, high temperature resistant low temperature resistance, low inductance, low noise, green environmental protection, low smoke zero halogen, ant rat resistance, waterproof and moistureproof, and a series of unique properties and the special structure of cable products, and have formed a certain productive forces. Along with the social requirements for security and system security, through the government, industry, enterprise's extensive publicity, promotion and cooperation, have a new technology of high performance and efficient security cable products will like the western developed countries, is widely used in security system.
Anytekabel Co.,Ltd. dedicated to the research and development and formation of flexible cable, the future will also be followed the pace of times, to create the application of flexible cable in security industry.

2015年10月7日星期三

Analysis of the minimum installation temperature of flexible cable

Flexible cable temperature and the minimum installation of PVC cable material of low temperature brittle temperature must be inseparable relationship. But how do corresponding relationship, have yet to have authority report. Generally higher than the brittle temperature 5 ℃, the probability of impact test specimen cracking is zero. Theoretically, if the impact of the installation when laying at this moment, less than under the condition of test impact can be construction. But here involves a variety of cable type and construction specification and the testing data of the practice of support.
If you want to truly understand the installation temperature and material laying low temperature brittle temperature relations, is a larger research project, from materials, cables, construction construction (or copy) and so on each link of sampling test, the system to find the critical point of damage, so need a lot of resources and manpower support. Once the figure it out, in turn, to the enterprise is also a great feedback.
If there is really no authoritative data support, to GB/T12706 standard higher than the sheath brittle temperature 20 ℃, laying temperature for a given installation. Though with a difference of 20 ℃ to install laying temperature not so accurate, safe allowance is very big, but definitely not due to the construction temperature cracking quality problems. Differ 15 ℃ installing laying temperature is ok, but must strictly control cable type and construction.

2015年9月21日星期一

Oil resistant PVC insulated & sheathed Control flex Screened cable

Oil resistant PVC insulated & sheathed Control flex Screened cable
Construction:
Conductor: bare copper strands
Insulation: special heat resistant PVC
Colour code: black cores with consecutive numbers
Stranding: in layers
with PETP foil over the outer layer
Screen: tinned copper braiding
Sheath material: special heat resistant PVC
Sheath colour: grey (RAL 7000)
Technical data
Nominal voltage: DIN VDE UL/CSA  Uo/U 300/500 V 600 V
Testing voltage U: 3000 V   core/screen: 1000 V
Min. bending radius fixed laying: 5 x d   flexible application: 10 x d
Radiation resistance: 8 x 107 cJ/kg
Temperature range: DIN VDE UL/CSA   fixed laying: -40/+90 °C up to +105°C
flexible application: +5/+90 °C up to +105°C    short time use: +105 °C
Fire performance: flame retardant and self-extinguishing acc. to
IEC 60332-1-2 + EN 60332-1-2,    UL VW-1, CSA FT1 FT2
Temperature range up to + 105°C
Oil resistant cable
www.anytecable.com


2015年9月14日星期一

Anyte LAN CABLE UTP Cat6

LAN CABLE UTP Cat6

The twisted pair lan cable cat6 used for digital communications , applied in buildings cabling system between patch panels and the output of communication.also used in Residential cabling system between the patch panel and output of communication ,meet the 100MHz data communication. Comply with color coding standard of ANSI/TIA/EIA-568-B

Conductor:Solid or stranded with 7 pieces (tinned) copper wire
Meet the UL444 standard HDPE polyethylene insulated
Two-cores twisted pair, total of four pairs,filled by plastic cross
Special aluminum mylar 100% coverage
drain wire:Single or stranded fine (tin plated) copper wires
(Tinned) copper braid or spiral shielding , coverage rate of 85%
Special PVC outer sheath, or a higher standard of low smoke zero halogen flame retardant outer sheath (optional materials can be customized colors)

Comply with standard UL758,UL1581,UL444,TIA/EIA-568,CSA C22.2, ISO/IEC 11801
Transmission frequency of 100MHz, and support for duplex applications
Comply with RoHS standards
Pass UL VW-1 & CSA FT1 vertical flame test

Operating voltage: 30V
Operating temperature range:
Movable Installation: - 5 ° C to +80 ° C fixed installation: -40 ° C to +80 ° C
Flammability rating: IEC60332-1 CM
DC Resistance at 20 ℃ (Ω / KM) <93.8
Operating Temperature 70 ℃
68% of the propagation velocity
Impedance (ohms) 100 ± 15
Flame Propagation Test to IEC 60332 Part 1 (LSOH) Flame Propagation Test to IEC 60332 Part 1 and Part III (LSFROH) halogen acid gas emissions in line with the IEC 60754, Part 1
Smoke emissions tested comply with IEC 61034

2015年9月9日星期三

The reason for ageing of cable

Wire and cable insulation aging is the most direct reason for lower breakdown.Guide min insulation lower mean a lot, according to the practical operation experience, is classified into the following several ways.
Anyte wire cable

1) the external force damage.Now quite a number of cable fault are caused by mechanical damage.Such as: non-standard cable laying installation construction, easy to cause mechanical damage;Sometimes if the injury is not serious, months or even years to lead to injury completely breakdown failure formation, sometimes destroyed fault may occur, directly affect the safety in production.
2) insulation be affected with damp be affected with damp.It is also very common.Such as: cable joint production of unqualified and do joint in humid climate conditions, can make the joint water or mixed with water vapor, time is long gradually damage the insulation of the cable strength and cause failure.
3) the chemical etching.Protective layer due to the long suffering chemical corrosion and electrochemical corrosion, the coating failure, the insulation is reduced, can also lead to cable fault.
4) long-term overload operation.Overload for a long time running, the high temperature will accelerate aging of the insulation, and insulation breakdown.Especially in hot summer, the temperature of the cable often resulted in the breakdown of cable insulation is weak at first, so in the summer, the failure of the cable is much more special.
But Anytekabel Co.,Ltd., the production of wire and cable, cable from the selection of raw materials or are strictly controlled in the process of production, control, makes every effort to do wire, cable, good let you rest assured brand!

2015年9月6日星期日

Introduction of the flexible cable

Flexible cable - is drag chain movement system, the power transmission material, cable of choice for signal transmission carrier, also known as: drag chain cable, towing cable, mobile cable, robot cable, etc.
Flexible cable conductor structure mainly according to DIN VDE and IEC 228 standard 0295 stranded copper wire structure, sheathed with low viscosity, more Flexible wear-resisting material, to slow the cable wear rate in the continuous moving back and forth.
Flexible cable according to the functional division is mainly divided into: sensor/encoder cable, servo motor cable, robots cable, clean cable, drag chain cable system.
Anytekabel Co.,Ltd.

According to the model can be roughly divided into the following categories:
The flexible control cable
1. PVC sheathed flexible control drag chain cable, flame retardant CC101 bending radius: 8x
2. PVC sheathed flexible shielding control drag chain cable, flame retardant CC111 bending radius: 10x
3. PVC sheathed flexible control cable drag chain cable, flame retardant CC120 bending radius: 5x
4. PVC sheathed flexible shielding control drag chain cable, flame retardant CC121 bending radius: 8x
5. PUR sheath flexible control drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC127 bending radius: 8x
6. PUR sheath flexible control shielded drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC117 bending radius: 10x
7. steel wire braided flexible control drag chain cable, uv protection, good low temperature resistance, wear resistance, CC158 bending radius: 10x
8. PETP outer sheath flexible control drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC160 bending radius: 5x
9. PETP sheathed flexible control shielded drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC133 bending radius: 10x
Flexible power cable
10. PVC sheathed flexible power drag chain cable, flame retardant CC305 bending radius: 8x
11. PVC sheathed outside the shield flexible power drag chain cable, flame retardant CC336 bending radius: 10x
12. PETP outer sheath flexible shield drag chain power cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC358 bending radius: 10x
13. PETP outer sheath flexible shield power drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC371 bending radius: 8x
The flexible data/bus cable
14. PVC sheathed flexible drag chain cable block data. CC41 bending radius: 8x
15. PUR outer sheath flexible shield data drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC43 bending radius: 10x
16. PETP outer sheath flexible shield data drag chain cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC46 bending radius: 10x
17. PETP drag chain outer sheath flexible shield data cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC48 bending radius: 12x
Flexible servo cable
18. PUR outer sheath servo drag chain flexible shield cable, oil resistant, acid and alkali resistant, hydrolysis resistance, uv resistance, low temperature resistant, wear resistant, flame retardant CC46 bending radius: 10x